Battery Operated Magnetic Flow Meter
- Features
- Specification
- Model Selection
- Applications
- Download
The RBEFB series Battery operated Magnetic flow meter features:
- Wide pipe size range: DN10 to DN1200;
- Wide measuring range: velocity measurement range can be up to 0.01 m/s ~ 12 m/s
- Accuracy: 0.25%, 0.5% and 1% for optional
- Micro power design, five section 3.6 V lithium batteries(or double battery packages design), continuous uninterrupted work five to ten years, and replace the battery is convenient.
- The display USES a large screen LCD liquid crystal display; it can display instantaneous flow, velocity (line pressure), forward and reverse accumulated amount and alarm prompt flow parameters, etc.
- Measuring tube is dynamic and resistance components won't produce winding, blocking phenomenon, almost no pressure loss, but long-term reliable work continuously.
- Measuring stability: measuring accuracy from measured medium temperature, pressure, viscosity, density changes in the physical parameters.
- Pulse, RS232 / RS485 interface and GSM/GPRS wireless data remote transmission function.
- With data save function: can save 1000 groups of data flow, and data storage time interval can be arbitrary Settings and data query
- Menu language: English/Turkish/Portuguese/Spanish, other language can be customize
- With 3-point calibration report
- OEM flow meters are accepted
Question:
1. how the Magnetic flow meter working?
The RBEFB Battery Powered Electromagnetic Flow meter main technical parameters
Diameter |
DN3-DN800 |
Pressure |
0.6~4.0Mpa(Special pressure customizable) |
Accuracy |
±0.5%、±1.0%, ±1% |
Measuring range |
0.05 ~ 15m / s |
Media Measurement (conductivity) |
> 20μs/cm |
medium temperature |
-10 ℃ ~ 90 ℃, ≤160℃(Remote type) |
ambient temperature |
-20 ℃ ~ 50 ℃ |
power supply |
3.6V/DC built-in lithium battery-powered, continuous working hours, more than 6 years |
Electrode materials |
316L stainless steel, HC, HB, titanium, tantalum, platinum / iridium alloy |
lining materials |
poly chloroprene rubber, polyurethane rubber, PTFE, F46, PFA |
Connections |
flange type, plug-in, clip pattern |
Structure in the form of |
a body divided body |
Level of protection |
IP65, IP67, IP68 |
Display |
large-screen LCD device for displaying instantaneous flow velocity, forward / reverse cumulative total and alarms |
Output |
pulse output 0.0001-10m3/p |
|
frequency output 1-5000Hz (passive opt coupler output) |
Recording data |
total accumulated flow |
Means of communication |
RS485, GSM / GPRS / CDMA wireless data transmitting |
System alarms |
Fluid empty pipe detection alarm, excitation current detection alarm, battery capacity detection alarm; |
Scaled output signal |
pulse per unit volume flow |
Humidity |
≤95% (relative humidity) |
The RBEFB Battery Powered Magnetic Water Flow Meter Model Selection
RBEFB- |
DN |
- |
|
- |
|
- |
|
- |
|
- |
|
- |
|
- |
|
- |
|
- |
|
- |
|
- |
|
- |
|
- |
|
|
1 |
|
2 |
|
3 |
|
4 |
|
5 |
|
6 |
|
7 |
|
8 |
|
9 |
|
10 |
|
11 |
|
12 |
|
13 |
|
14 |
1 Nominal Diameter(mm)/ [inches] (1)
|
|||||||||||||||||||||||||||||
2 Flange Rating (1)
|
- Raw water, potable water management
- Utilities, Waterworks, water system
- Water revenue metering for accurate billing
- Wastewater flow monitoring
- Monitoring of distribution networks
- Pipeline leakage detection and Leakage Detection Solution
- Water distribution network monitoring and remote locations
- Pump performance monitoring;
- Well chambers, Groundwater Monitoring and Management Solutions
- Measuring water consumption
- Agriculture irrigation water metering
2. Battery Operated Magnetic Flow Meter Manual