Home Products Show > > Magnetic Flow Meter > Ceramic Liner Electromagnetic Flow Meter
Products Visitors::1102

Ceramic Liner Electromagnetic Flow Meter

  • Model:RBEF
    • Features
    • Specification
    • Model Selection
    • Applications
    • Download
    The RBEF Ceramic Electromagnetic flow meters(DN3 to DN200) are excellent for abrasive fluid because of Ceramic lining giving the unit a very stable output even for slurry fluid measurement. The Electromagnetic flow has ceramic liners in place of the typical liners commonly used in magnetic flow meters. Ceramic liners can tolerate higher temperatures and pressures than most other liner materials. Other liners can also release plasticizes and drying agents into the product in a process referred to as leaching.

    RBEF Ceramic liner Electromagnetic Flow meter Features
    • Diameter range of DN15 up to DN200, DN15...100: PN 40, DN150...200: PN16 or PN 100.
    • Process connector: Wafer or Flanges and Thread type(for low flow meter)
    • Stable measurement in noisy applications
    • Highly aggressive and abrasive fluids for slurry applications.
    • Tube with high-tech ceramic material, fulfilling fully vacuum-resistant.
    • Special tube design with conical parts, optimizing the flow profile.
    • The smooth and pore free ceramic tube construction does not leak.
    • Insensitive for temperature shocks, exceptional long-term stability and accuracy.
    • Excellent chemical and abrasion resistance, fulfilling requirements of the chemical industry.
    • Improved safety with absolute leak tight design making it highly suitable for hygienic applications.
    • Ceramic lined detectors provide reliable service in the most severe applications such as high temperature, high pressure and extreme abrasion

    The RBEF series Ceramic liner Electromagnetic Flow meters Specification:
    • Diameter range of DN15 up to DN200, DN15...100: PN 40, DN150...200: PN16 or PN 100.
    • Mounting: Tri-clamp or Wafer or Thread type
    • Process temperature: Min.: -40 °C (-40 °F); Max.: 180 °C (356 °F)
    • Flow velocity: Min.: 0.25 m/s (0.82 ft/s) Max.: 12 m/s (39.37 ft/s)
    • No moving parts;
    • Fluid: for liquids
    • Material: Ceramic liner and Electrode,
    • Accuracy : 0.5% or 0.25%
    • Other characteristics: compact and remote type
    • Protection level: IP65 or IP67
    • Domain: Highly aggressive and abrasive fluids, 
    • Process pressure: 9.8 bar (142.14 psi)



    RBEF Ceramic Liner Electromagnetic Flow meters Model Selection: 

    RBEF-

    DN

    -

    -

    -

    -

    -

    -

    -

    -

    -

    -

    -

    -

    -

     

     

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

    11

    12

    13

    14

    15


    1 Nominal Diameter(mm)/ [inches](1)

    0015 [½”]

    0100 [4”]

       

    0020 [¾”]

    0125 [5”]

       

    0025 [1”]

    0150 [6”]

       

    0032 [1¼]

    0200 [8”]

       

    0040 [1½]

         

    0050 [2”]

         

    0065 [2½]

         

    0080 [3”]

         

    2 Flange Rating(1)

    02

    0.25 MPa

    1600 … 3000

    06

    0.6 MPa 

    700 … 3000

    10

    1.0 MPa 

    200 … 1400

    16

    1.6 MPa 

    15 … 600

    40

    4.0 MPa 

    15 … 150

    AA

    Special

     

     

    3 Electrode Material

    1

    316L Stainless Steel

    3

    Hastelloy C-22

    4

    Hastelloy B-10

    5

    Titanium

    6

    Tantalum

    7

    Platinum / Iridium Alloy

    8

    Tungsten Coated Stainless Steel

    9

    ceramic

    4 Lining Material

    1

    Ceramic

     
    15 … 200
         
         

     

    5 Grounding and Lining Protection 

    0

    Flange ground

    15 … 3000

    1

    Earth ring

    15 … 250

     2

    Ground electrode

    50 … 3000

    3

    Inlet protection ring

    50 … 3000

    6 Max. Process Temperature 

    A

    80°C

    All Linings

    B

    120°C

    Neoprene / PTFE / PFA / Tefzel

    C

    180°C

    PTFE only

    7 Environmental Protection Class

    1

    IP65

    2

    IP67 (Compact Type Only)

    3

    IP68 (Remote Type Only)

    8 Explosion Proofing

    1

    None

    2

    Ex DE IIC T6

    9 Configuration – sensor/transmitter 

    1

    Compact (15 … 1000)

    2

    Remote (with 10m cable)(2)

    10 Power Supply

    A

    AC: 85 … 265 VAC / 45 … 63Hz

    D

    DC: 18 … 36 VDC

    11 Display and Programming

    2

    2 line LCD display + keypad programming

    3

    3 line LCD display + keypad programming

    12 Output and Input

    0

    Basic Configuration (current, pulse and contact outputs)

    2

    Basic Configuration + RS485

    3

    Basic Configuration + GPRS

    4

    Basic Configuration + MODBUS

    13 Calibration Specification

    1

    3 point, 0.5% accuracy

    2

    3 point, 0.25% accuracy

    3

    Special

    14 Flow Tube Configuration

    W Wafer 15 to 200
     F  Flange

     15 to 200

     T

    15 Special Function

     

    0

    No

    R

    IR Remote

    T

    Power off timer

    H

    Cumulative hours

    Q

    Quantitative control

    J

    Relay Output


    The RBEF Ceramic Liner Electromagnetic Flow meters Applications
    • Chemical Industries (Including: Corrosive liquid, chemicals, dyes, Toxic, aggressive and abrasive mediums etc.)

    • Food & beverage Industries(Like: Oil-based products: vegetable oils; Dairy products: fat creams, milk, cheese, yogurt with fruit particles)
    • Pharmaceutical Industries: 
    • Paper & pulp Industries (Including: Liquid, corrosive liquids, pulp, chemicals, etc)
    • Wastewater Industries (Including:Abrasive slurring)
    • Machine building Industries: Emulsions: latex, emulsion paints; Adhesives; Fibrous products
    • Primaries Industries
    • Cement