Electromagnetic Flow Meter
- Features
- Specification
- Model Selection
- Applications
- Download
- No moving parts to wear and tear
- Compact and Remote type;
- A wide range of meter sizes, from DN10 - DN3000 (½” - 120”) to tackle any application
- Standard 0.5% accuracy, 0.2% accuracy for optional
- Measure clean liquids as well as mixtures of solids and liquids with conductivity as low as 5 μS/cm;
- Totalizers for positive, negative, and net flow
- Short straight-pipe run required, thus, suitable for any desired installation location
- Plug and play. All parameters are pre-configured in factory
- No pressure loss
- Special function: IR Remote, Power off timer, Cumulative hours, Relay Output
- Rich communication outputs: 4-20mA, Pulse, RS485/232, Optional Modbus, HART, Profibus and GPRS/GSM communication interface
- Self-diagnosing capability to minimize operational downtime;
- OEM customer service
Other question about Electromagnetic Flow meters:
- what's the Electromagnetic flow meter working principle?
ANS: The measuring principle of the Electromagnetic flow meter (Mag flow meter) is based upon the Faraday's Law of electromagnetic induction.
2. How to use Magnetic flow meters?
ANS: Flow sensor is maintenance free, no moving part, easy to use them.
3. How to select Electromagnetic flow meters?
ANS: provide the key technical information to us or select the model according to Magnetic flow meter model selection. If you have special technical demands, before you order the Magflow meters, please clarify them.
RBEF Main powered(AC/DC) Electromagnetic Flow meters Specifications
Sizes |
Flanged (Metric) |
DN15…DN3000 |
||||||
Flanged (US) |
1/2”…118” |
|||||||
Wafer Design |
DN15…DN100 |
|||||||
Nominal Pressure |
GB,JIS and DIN Flange |
0.6 MPa, 1.0 MPa, 1.6 MPa, 4.0 MPa |
||||||
ANSI Flange |
Class 150, Class 300 |
|||||||
Wafer Design |
1.6 MPa, 4.0 MPa |
|||||||
For additional pressure requirements, please contact manufacturer |
||||||||
Accuracy (pulse output) |
Standard |
±0.5% (0.6m/sec to 12 m/sec) |
||||||
Optional |
±0.2% (1.0m/sec to 12 m/sec) |
|||||||
Measurement Resolution |
±1mm/sec |
|||||||
Max Flow Tube Velocity |
SI: |
49 ft/s |
||||||
US: |
12 m/s |
|||||||
Ambient Temperature |
-25…+55°C / -13…+131°F |
|||||||
Relative Humidity |
5%…90% |
|||||||
Conductivity |
≥5 μS/cm |
|||||||
Magnetic Transmitter Mounting Availability |
Compact type |
Sizes: DN15…DN1000 1/2”…40” |
||||||
Remote type |
Sizes: DN15…DN3000 1/2”…118” |
|||||||
Note 1: Cable between flow tube and remote transmitter is type SMFE100 Note 2: Remote unit supplied with 10m cable as standard Note 3: Max cable length is 200m (650ft) |
||||||||
|
Material |
SI |
US |
|||||
Liner Material Options |
Neoprene (std) |
DN15…DN3000 |
1/2”…118” |
|||||
PTFE |
DN15…DN1000 |
1/2”…40” |
||||||
Polyurethane |
DN15…DN300 |
1/2”…12” |
||||||
PFA |
DN15…DN250 |
1/2”…10” |
||||||
PFA with optional wire reinforcement |
DN80…DN250 |
3”…10” |
||||||
Tefzel |
DN15…DN250 |
1/2”…10” |
||||||
Tefzel with optional wire reinforcement |
DN80…DN250 |
3”…10” |
||||||
|
ceramic liner and electrodes |
DN15…DN200 |
1/2”…8” |
|||||
Electrode Material Options |
316L stainless steel (std) |
DN15…DN3000 |
1/2”…118” |
|||||
Hastelloy – C22 |
DN15…DN1000 |
1/2”…40” |
||||||
Hastelloy – B10 |
DN15…DN1000 |
1/2”…40” |
||||||
Titanium |
DN15…DN250 |
1/2”…10” |
||||||
Tantalum |
DN15…DN250 |
1/2”…10” |
||||||
Platinum/iridium Alloy |
DN15…DN250 |
1/2”…10” |
||||||
316L with tungsten carbide coating |
DN15…DN600 |
1/2”…24” |
||||||
Grounding Options |
Flange Grounding |
DN15…DN3000 |
1/2”…56” |
|||||
Grounding Ring |
DN15…DN250 |
1/2”…10” |
||||||
Electrode Grounding |
DN50…DN3000 |
2”…118” |
||||||
Inlet protection ring |
DN50…DN300 |
2”…12” |
||||||
|
Type |
Liner |
Standard |
Optional |
||||
Max Process Temperature Limits |
Compact |
Neoprene |
80°C / 176°F |
120°C / 248°F |
||||
PTFE |
80°C / 176°F |
120°C / 248°F |
||||||
Polyurethane |
80°C / 176°F |
- |
||||||
PFA |
80°C / 176°F |
120°C / 248°F |
||||||
Tefzel |
80°C / 176°F |
- |
||||||
Remote |
Neoprene |
80°C / 176°F |
120°C / 248°F |
|||||
PTFE |
80°C / 176°F |
120°C / 248°F 180°C / 356°F |
||||||
Polyurethane |
80°C / 176°F |
- |
||||||
PFA |
80°C / 176°F |
120°C / 248°F |
||||||
Tefzel |
80°C / 176°F |
- |
||||||
Environmental Protection Class |
Compact |
IP 65 |
IP67 |
|||||
Remote |
IP 65 |
IP 68 |
||||||
Power Supply Options |
85…265VAC / 45…63Hz, 20VA |
|||||||
16…36VDC, 16VA |
||||||||
Display |
2 or 3 line backlit LCD |
|||||||
Configuration Access |
Front panel keypad |
|||||||
Hand held infrared remote control (optional) |
||||||||
Output Signals |
Active analog current output |
Max load resistance 0…1.5kΩ for 0…10mA 0…750Ω for 4…20mA |
||||||
Accuracy = same as pulse output ±0.1% of rate |
||||||||
Option: HART Protocol |
||||||||
Passive analog current output |
Requires 24Vdc external supply to operate |
|||||||
Accuracy = same as pulse output ±0.1% of rate |
||||||||
Pulse / frequency and alarm outputs |
Optically isolated open collector output powered either internally or externally Int. power: 28VDC with 1.2kΩ pull-up resistor Ext. power: ≤36VDC, max current 250mA |
|||||||
Digital Communications |
RS485 Modbus |
|||||||
GPRS (superimposed on current output) |
||||||||
All interfaces have built in lightning protection |
||||||||
Electrical isolation |
Isolation between all I/O and input power no less than 500V |
|||||||
Isolation between all I/O and ground no less than 500V |
||||||||
Isolation between flow tube and tr |
The RBEF series Electromagnetic Flow Meter Model Selection
RBEF- |
DN |
- |
|
- |
|
- |
|
- |
|
- |
|
- |
|
- |
|
- |
|
- |
|
- |
|
- |
|
- |
|
- |
|
|
|
|
1 |
|
2 |
|
3 |
|
4 |
|
5 |
|
6 |
|
7 |
|
8 |
|
9 |
|
10 |
|
11 |
|
12 |
|
13 |
|
14 |
15 |
16 |
1 Nominal Diameter(mm)/ [inches] (1)
|
||||||||||||||||||||||||||||||||||||
2 Flange Rating (1)
|
||||||||||||||||||||||||||||||||||||
3 Electrode Material
|
||||||||||||||||||||||||||||||||||||
4 Lining Material
|
The general purpose AC/DC powered Magnetic Flow Meters Typical Applications
- Water/wastewater industry, wastewater treatment;
- Chemical, oil and gas
- Metals and mining, Industrial / process water
- Food and beverage,
- Pharmaceutical
- Power plants
- Pulp and paper,
- Pump stations
- Groundwater / Agriculture, Municipal waterworks
- Cooling towers