The RBFM-F Fixed type clamp-on Ultrasonic Flow Meter is a a non-intrusive flow measurement that measures volumetric flow, low cost transit-time ultrasonic flow meter with clamp-on(strap-on) transducers for non-invasive liquid flow rate measurement.
The RBFM-F Fixed type Clamp-on Type Ultrasonic Flow Meter Advantage:
- Cost-effective and easy installation
- Transducers for wide pipe sizes ranging from15 to 6000 mm (½" to 240").
- Wide range velocities of ±0.1~ ± 12m/s (0.03 ~ ± 105 feet/sec.)
- High accuracy of ± 1% of reading
- Suitable for a wide variety of liquid types
- Fast response time - less than 1 second.
- 2 line LCD display with flow rate, totalizer & signal condition.
- 0-20mA & 4-20mA outputs, RS-232 communication, user-selectable engineering units, and a data logger function
- Clamp-on transducers feature integral magnet for installation
- Data logger function includes date, totalizer, & signal condition diagnostic
The RBFM-F-F Fixed(Wall mounted) Clamp-on Type Ultrasonic Flow Meter Specification
Transducer |
Standard Type |
S type |
Pipe size |
(15 mm ~ 100 mm) ½" ~ 4" |
||||||
SN |
SH |
-30~160℃ |
||||||||
Size(mm) |
SN |
45×25×28 |
||||||||
M Type |
Pipe size |
50 mm ~ 700 mm (2" ~ 28" ) |
||||||||
Temp. |
MN |
-30~160℃ |
||||||||
Size(mm) |
MN: |
64×35×32 |
||||||||
L Type |
Pipe size |
300~ 6000(12" ~ 240" ) |
||||||||
Temp. |
LN |
-30~160℃ |
||||||||
Size(mm) |
LN |
97×54×53 |
||||||||
|
Insertion Type |
Pipe size |
80~6000mm |
|||||||
Temp. |
RCN |
-40 ~ 160℃ |
||||||||
RCL(Extended) |
-40 ~ 160℃ |
|||||||||
Temp. Sensor |
|
Pt100 3 wires |
||||||||
|
Pt100 3 wires(only for small pipes) |
|||||||||
Fluid |
Water, sea water, industrial sewage, acid & alkali liquid, alcohol, beer, all kinds of oils which can transmit ultrasonic single uniform liquid |
|||||||||
Flow Direction |
Bi-directional measuring, net flow/heat measuring |
|||||||||
Accuracy |
± 1% ~ ± 2% of reading (1.5 ~ 100 feet/sec.) |
|||||||||
Repeatability |
± 0.2% of reading |
|||||||||
Flow rate range |
0.01 ~ ± 12 m/s |
|||||||||
Response Time |
Less than 1 second |
|||||||||
Keypad |
16 Key with tactile action |
|||||||||
Pipe Material |
Steel, stainless steel, cast iron, cement pipe, copper, PVC, aluminum, FRP etc. Liner is allowed |
|||||||||
Liner Material |
Tar Epoxy, Rubber, Mortar, Polypropylene, Polystryal, Polystyrenes, Polyester, Ebonite, Polyethylene, Teflon, etc. |
|||||||||
Mounting |
wall mounting, local |
|||||||||
Display |
2 Line LCD with backlight; 5 digits with decimal point for flow rate, 8 digits for Forward, Reverse & Net totalized values |
|||||||||
Output |
Analog |
4-20mA or 0-20mA current output. Impedance 0∼1kW. Accuracy 0.1%. |
||||||||
Relay output |
Over 20 source signal (no signal, reverse flow etc.) |
|||||||||
Pulse Output |
Frequency signal :1~9999 Hz |
|||||||||
Input |
Three analogue input |
|||||||||
Three-wire PT100 resistor input (optional) |
||||||||||
Other functions |
Automatically record the totaliser data of the last 64 days / 64 months / 5 years; The power-on time and corresponding flow rate of the last 64 power on and off events. Allow manual or automatic flow loss compensation The instrument working status of the last 64 days |
|||||||||
Communication |
RS-232/RS485 |
|||||||||
Alarm |
High/Low with buzzer |
|||||||||
Protection |
Transmitter |
IP 65 |
Sensor |
IP67/IP68 (optional) |
||||||
Straight pipe section |
In the upstream it must be beyond 10D, in the downstream it must be beyond 5D, in the upstream the length must be beyond 30D from the access of the pump. (D stands for pipe diameter) |
|||||||||
Cable Length |
Twisted Pair Line, standard length of 10m, can be extended to 500m (not recommended); Contact the manufacturer for longer cable requirement. RS-485 interface, transmission distance up to 1000m |
|||||||||
Power Supply |
Remote Type |
90 ~ 260VAC 50/60 Hz; 9-28VDC |
||||||||
Compact Type |
9-28VDC |
|||||||||
Power Consumption |
Less than 2W |
|||||||||
Data Storage |
Operation parameters and tantalization data are stored in EEPROM for more than 10 years |
|||||||||
Engineer Unit |
M3, Liter, US gallon, Imperial gallon, Million gallons, Cubic feet, US Barrels, Imperial barrels, Oil barrels |
|||||||||
Time Units |
Second, Minute, Hour, Day |
|||||||||
Protocols |
MODBUS, M-BUS, Fuji extended protocol and other factory protocol |
|||||||||
Humidity |
Main Unit: 85% RH |
|||||||||
Remarks: With a high strength carrying case suitable for normal and harsh environment |
RBFM-F-F Fixed(Wall mounted) Clamp-on Ultrasonic Flow Model Selection
RBFM |
X |
|
X |
X |
DNxx |
X |
X |
|
X |
X |
X |
|
|
Instrument Type |
|
||||||||||
F |
Ultrasonic Flowmeter |
|||||||||||
H |
Ultrasonic Heat meter |
|||||||||||
|
Power supply |
|||||||||||
A |
220VAC |
|||||||||||
D |
24VDC |
|||||||||||
B |
Battery |
|||||||||||
|
Flow/Heat meter Type |
|||||||||||
F |
Fixed type |
|||||||||||
H |
Handheld type |
|||||||||||
F |
Flanged type |
|||||||||||
B |
Battery type |
|||||||||||
|
|
|
|
Transducer Type |
||||||||
|
SN |
S type(pipe size: 15-100mm, temp.: -30 to 90℃) |
||||||||||
SH |
S type(pipe size: 15-100mm, temp.: -40 to 160℃) |
|||||||||||
SPMN |
S type with mounting frame only for Handheld (pipe size: 15-100mm, temp.: -40 to 90℃) |
|||||||||||
SPMH |
S type with mounting frame only for Handheld(pipe size: 15-100mm, temp.: -40 to 160℃) |
|||||||||||
MN |
M Type(pipe size: 50-700mm, temp.: -30 to 90℃)) |
|||||||||||
MH |
M Type(pipe size: 50-700mm, temp.: -40 to 160℃)) |
|||||||||||
MPMN |
M type with mounting frame only for Handheld (pipe size: 50-300mm, temp.: -40 to 90℃) |
|||||||||||
MPMH |
M type with mounting frame only for Handheld (pipe size: 50-300mm, temp.: -40 to 160℃) |
|||||||||||
RB-1 |
extended the mounting frame, for pipe:DN300-700mm, temp.: -40 to 90℃ |
|||||||||||
RBH |
extended the mounting frame, for pipe:DN300-700mm, temp.: -40 to 90℃ |
|||||||||||
LN |
L type(pipe size: 300-6000mm, temp.: -30 to 90℃) |
|||||||||||
LH |
L type(pipe size: 300-6000mm, temp.: -40 to 160℃) |
|||||||||||
I |
Insertion Type |
|||||||||||
IE |
Extended type |
|||||||||||
F |
Flanged type |
|||||||||||
|
Pt100 |
Temperature sensor |
||||||||||
|
DNxx |
Pipe size |
|
|||||||||
|
|
Pipe material |
|
|||||||||
|
C |
Carbon Steel |
||||||||||
SS |
Stainless Steel |
|||||||||||
CI |
cast iron |
|||||||||||
F |
Fibreglass |
|||||||||||
P |
PVC |
|||||||||||
C |
cement pipe |
|||||||||||
X |
Others, clarify |
|||||||||||
|
X |
Pressure(MPa) |
||||||||||
|
Output |
|||||||||||
N |
NO |
|||||||||||
A |
4-20mA |
|||||||||||
P |
Pulse |
|||||||||||
R |
Relay |
|||||||||||
2 |
RS232 |
|||||||||||
4 |
RS485 |
|||||||||||
5 |
Datalogger |
|||||||||||
|
Input |
|
||||||||||
N |
NO |
|||||||||||
1 |
1*4-20mA |
|||||||||||
2 |
2*4-20mA |
|||||||||||
3 |
3*4-20mA |
|||||||||||
|
Cable length |
|||||||||||
X |
meter |
RBFM-F-F Fixed(Wall mounted) Clamp-on Type Ultrasonic Flow Meter Applications:
- Water distribution flow metering
- HVAC industry
- Leak detection
- Chemical and Pharmaceutical industry
- Hygienic Food and Drinking flow monitoring
- Steel industry
- Power, energry management
- Protec Chemical and oil industry
- Irrigation water metering;
- Checking fixed installation flow meters
- Survey water works