Modelo: RBDOF-F
Fixed Doppler ultrasonic flow meter for open-channel and partially-filled pipe flow with dual-depth area-velocity technology.
| Type | Fixed Doppler area-velocity, open channel / partially filled pipe |
| Accuracy | Velocity ±1%~±3%; water depth ±3 cm |
| Level range | Pressure type 0.02–3 m or 0.02–10 m |
| Temperature |
The RBDOF-F is a fixed-installation Doppler flow meter for open channels and partially-filled pipes carrying dirty liquids, slurries and stormwater. Dual-depth technology combines pressure and backup ultrasonic level measurement, and self-transmitting/receiving mode keeps working at very low water levels.
Automatic flow calculation supports circular, rectangular, trapezoidal and U-shaped channels, with RS485/Modbus and 4–20 mA outputs for remote monitoring.
Dónde se instala habitualmente este medidor. Cada escenario enlaza con la aplicación completa.
El RBDOF-F ofrece una precisión de Velocity ±1%~±3%, level ±3 cm, verificada mediante nuestro proceso de calibración de fábrica bajo ISO 9001.
El RBDOF-F está disponible para tuberías desde Open channel / partially filled pipe, cubriendo un amplio rango de caudales industriales.
El RBDOF-F admite salida RS485 Modbus RTU, 4-20mA, RS232 (model dependent) para integrarse con su sistema de control.
Battery-powered insertion ultrasonic water meter for agricultural irrigation and water supervision, with IP68 protection and no pressure loss.
Inline flanged transit-time ultrasonic flow meter for industrial water and process liquids, factory calibrated with no moving parts and zero pressure drop.
Inline ultrasonic micro-flow sensor measuring 1–100 mL/min with millisecond response, no moving parts and a biocompatible PEEK fluid path.
Última actualización: 18 de octubre de 2026
Contacte a nuestro equipo de ventas para obtener precios, consulta técnica o una solución personalizada para su aplicación.
Solicitar Cotización Ahora| Operation -5°C ~ +60°C; storage -25°C ~ +80°C |
| Output signal | RS485 (Modbus RTU), 4–20 mA, RS232 (model dependent) |
| Power supply | 10–30 VDC (12 VDC / 24 VDC options) |
| Protection | IP68 (sensor); IP65 (transmitter) |
La selección depende de la conductividad del fluido, el diámetro de tubería, la temperatura y los requisitos de precisión. Los medidores electromagnéticos son aptos para líquidos conductores, los ultrasónicos para tuberías grandes y líquidos limpios, y los de vórtice para vapor, gas y líquidos. Contacte a los ingenieros de R&B Instrument Inc. para una recomendación.